Instruction Manual
αlpha-CON1000
Conductivity Controller/Transmitter
MEAS
8.088.08
mS
25.025.0
o
C
ATC
Conductivity Controller
ααlpha CON1000
CAL
ENTER
ALARM
REL A
REL B
AUTO
MANU
REL A
REL B
ESC
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - 8.088.08

68X216802 Instruction Manualαlpha-CON1000Conductivity Controller/Transmitter MEAS 8.088.08mS25.025.0oCATCConductivity Controllerα

Page 2 - TABLE OF CONTENTS

68X216802104.3 Control ConceptThe main function and sub-function groups are organised in a matrix format as shown below. Thesefunctions can be access

Page 3 - 1 Introduction

Operating Instructions αlpha-CON100068X216802115 MEASUREMENT5.1 Display in Measurement modeWhen the controller is initially powered on, it automatical

Page 4 - 1.2 Applications

68X21680212NOTE: To view (not change) the SETUP parameters, push the ENTER key when the security codereads “000”.

Page 5 - 2 Assembly and Installation

Operating Instructions αlpha-CON100068X216802135.2.1.1 Clearing the Calibration security code from the displayThe calibration security code automatica

Page 6 - Electrical Connection

68X216802 6 Calibration ModeYou can reach the Calibration mode directly from the Measurement mode by pressing the CAL key andentering the Calibra

Page 7 - 3.2 Back Panel

68X216802 7 ADVANCED SET-UP MODE7.1 Temperature Coefficient sub-functionThis sub-function allows you to select the correct temperature coefficien

Page 8 - -8.8.8.8-8.8.8.8

68X216802 7.2 Temperature calibration (ATC mode only)1) Select “ATC on” as described above in Section 7.4.1.2) Press the ENTER key. The upper dis

Page 9 - ConCon

Operating Instructions αlpha-CON100068X216802177.3 Control Relay A/Control Relay B (SP1/SP2) sub-functionThe SP1 option sets the operating parameters

Page 10 - 4.3 Control Concept

68X21680218Example: You have set your set point 1 (Lo) at 6.00 µS and your hysteresis limit value is at 0.50 µS. Ifyour measured value undershoots the

Page 11 - C.CdC.Cd

Operating Instructions αlpha-CON100068X216802197.4 Controller (Cntr) sub-functionYou can set the controller’s parameters in this sub-function.7.4.1 En

Page 12 - 68X216802

68X2168022PrefaceThis manual serves to explain the use of the αlpha-CON1000 series Conductivitycontroller/transmitter. The manual functions in two way

Page 13

68X216802 7.4.3 Choosing break/make contact relay typeNote: If the controller type “oFF” is set, the parameters listed in 7.5.3, 7.5.4, 7.5.5 and

Page 14 - 14131413

Operating Instructions αlpha-CON100068X216802217.6 Current Output (rng) sub-functionThis sub-function lets you set the transmitter current output rang

Page 15 - 2.102.10 %%

68X216802228) Press the ENTER key to confirm your selection.9) Press the ENTER key to return to Advanced Set-up mode, or return to Measurement mode by

Page 16 - 25.025.0

Operating Instructions αlpha-CON100068X216802231) Follow directions in 7.9.2 to enter Configuration mode.2) Press the ENTER key. Scroll with the ∆∆ or

Page 17 - SPSP 11

68X216802247.8.1 Entering Calibration mode from Advanced Set-up mode1) Enter Advanced Set-up mode. Push the ENTER key and scroll to Advanced Set-up se

Page 18 - OF.dOF.d

Operating Instructions αlpha-CON100068X216802259 Technical SpecificationsConductivity Range Resolution Default Cell Constant, K Optional Cell, K0.000

Page 19 - L.CtL.Ct

68X2168022610 AccessoriesAssembly AccessoriesProduct Description Code no.Conductivity Cell, up to 20µS; Cell constant, K=0.01 with integrated Pt 100,M

Page 20 - 200200..00

Operating Instructions αlpha-CON100068X2168022712 Appendices12.1 Appendix 1 – Jumper PositionsJumper Positions - Internal to the controllerJP 1 Select

Page 21

68X2168022812.2 Appendix 2 – Measurement Ranges available in the ControllerRange No. Range Resolution Default cell K10.000 – 1.999 µS 0.001 µS0.0120.0

Page 22 - StdyStdy

68X216802 Substance Concentration wt % Conductivity 10-4 S/cm ConductivityCoefficientH3PO410 566 1.04(15oC) 20 1129 1.1440 2070 1.5045 2087 1.615

Page 23 - FLEtFLEt

Operating Instructions αlpha-CON100068X21680237.4 Controller (Cntr) sub-function...197.5 M

Page 24 - 8 Auto/Manual Mode

68X2168023025 2810 1.66Substance Concentration wt % Conductivity 10-4 S/cm ConductivityCoefficientKBr 5 465 2.06(15oC) 10 928 1.9420 1907 1.77KCN 3.25

Page 25 - 9 Technical Specifications

68X216802 12.5 Appendix 5 - Simple Explanation on the Function of HysteresisThe controller relay activates when the set-point is reached. In the

Page 26 - 11 General Information

68X2168023212.6 Appendix 6 – General Instructions Concerning Controller SettingMINFunctionMAXFunctionXp = 0 Xp = 0SP 1SP 2+ Xw- XwYh0 %50 %100 %Contro

Page 27 - 12 Appendices

68X2168024• Three control modes: limit, proportional pulse length or proportional pulse frequency• Large dual display LCD for easy reading with clear

Page 28

68X216802 2 Assembly and Installation2.1 Measurement and Control SystemA typical measurement system consists of:• a αlpha-CON1000 process contro

Page 29

68X2168026The field-tested control panel housing is 96 x 96 mm; with protection class IP 54 (front).Electrical Connection3.1 Connection Diagram-+PE/SP

Page 30

Operating Instructions αlpha-CON100068X21680273.2 Back PanelThe back panel consists of two connectors. The first connector is the 17-way PCB edge conn

Page 31

68X216802 4 Overview4.1 Keypad and Display4.1.1 Keypad• Perform rapid calibration• Allows entry to Set up mode• Select individual functions with

Page 32

Operating Instructions αlpha-CON100068X21680294.2 Function GroupsThe main function and sub-function groups are organised in a matrix format for config